Input Power: 105-135 V; 50/60 Hz, 35 VA max.
Operating Temperature: -10 F to +130 F (-23.3 C to 54.4 C)
INPUT SIGNAL: M1890-R: Resolver Input AVG Automation's RL100, E7R, E8R, or RL101 series
M1890-S: Selsyn Input Signal: 3-wire, 148 k impedance, 48-90 V, L-L Reference: 2-wire, 105-135 V, 50/60 Hz, 35 VA max. Tracking Speed: 1800 RPM max Resolution: 8-, 10-, or 12-bits-per-revolution; 1 part in 100,000 total
PROGRAMMING:
Scale Factors: 0.001 to 65,535.999 in increments of 0.001 Preset Numbers: Multi-turn: 0 to 99,999 Single-turn: 0 to (Scale factor-0.001) Decimal Point: After any digit Freeze, Preset, Reset, and Supervisory Inputs:
Contact closure to signal reference or 5 V logic Logic TRUE: 0-1 VDC (4.7 k internal pull-up resistors) Logic FALSE: 4-5 VDC
Power Interruption and Watch-dog Relay: 1 Form C contact, 120 VAC, 1 A
PARALLEL POSITION OUTPUTS:
a) 1855 Parallel Bus (Standard): Compatible with AVG Automation's 1855 bus; 5-digit BCD; 5 V CMOS logic; Fan out of 1 driving LS TTL load; High Logic TRUE Logic TRUE: 2.4 V @ 1.6 mA PNP (sourcing) current Logic FALSE: 0.4 V @ 1.6 mA NPN (sinking) current Output Supply Current: 100 mA @ 5 VDC for logic 750 mA @ 12 VDC for limit outputs
Data Update Rate: 4 ms; Data on 1855 Bus is frozen when freeze input goes TRUE (30 ms).
|
Maximum distance between M1890 and 1855 limit modules:
3 ft (914.4 mm) ribbon (isolated from other wiring) and 100 ft (30.48 m) shielded cable (with CBL-E34MF)
b) Additional Parallel Output (Optional): Output Format: BCD, Binary, or Gray Code Output Interface: T, P, N, or C
T: LS TTL (74LS645): Logic TRUE: 2 VDC @ 15 mA, 20 mA leakage when tristated; Logic FALSE: 0.35 V @ 24 mA, 0.4 mA leakage when tristated MUX Input: Low-active TTL-level (i.e., Logic TRUE: 0-0.8 V max; Logic FALSE: 2-5V)
P: PNP source transistor: Logic TRUE: Transistor ON, 1.7 V drop @ 100 mA Logic FALSE: Transistor OFF, 0.2 mA leakage @ 50 V max.
N: NPN (sinking) transistor: Logic TRUE: Transistor ON, 1.1 V max @ 100 Ma Logic FALSE: Transistor OFF, 0.1 mA leakage @ 50 V max.
C: NPN sink transistor: Logic TRUE: Transistor OFF, 0.1 mA leakage @ 50V Logic FALSE: Transistor ON, 1.1 V max. @ 100 mA Data Update Rate: 4 ms Data Transfer Signal: Logic HIGH: 4 to 5 V Logic LOW: 0 to 1 V (edge-triggered) Transmission Distance: 50 feet (max.)
c) Serial Output (Optional):
Output-types: RS-232C or RS-422A Transmission Distance: RS-232C: 50 ft (15.24 m) max. RS-422A: 2000 ft (609.6 m) max., with shielded cable. Character Protocol: User-Definable
Baud Rate: Field-selectable 300, 600, 1200, 2400, 4800, and 9600 bps. |