Input Power:
AC: 120 VAC 10%, 7 VA: Optional 220, 240 VAC DC: 11-28 VDC, l00 mA (typical) exclusive of load, for outputs and control input
Operating Temperature: -10 F to +130 F (-23 C to +55 C) Position Transducer: AVG Automation's dual-resolver series, such as RL210.
Max. Resolution: 4096 counts/turn Scale Factor: automatic Output Update Rate: 1.4 ms Display Range: 6 digits (000.000 to 999.999) Decimal Point: fixed Position Sensor: Multi-turn (dual) resolver with gear ratio 4, 8, 16, 32, 64, 128, or 256:1, such as AVG Automation's RL210 Resolver Cable Length: 2500 ft. (762 m) max., shielded
OUTPUTS:
All outputs must be the same type; control inputs depend upon the type of outputs
Type of Outputs: P & N
P: PNP (sourcing) transistor: Logic TRUE: Transistor ON, 1.7 V drop @ 100 mA Logic FALSE: Transistor OFF, 0.2 mA leakage @ 50 V
N: NPN (sinking) transistor: Logic TRUE: Transistor ON, 1.1 V, max. @ 100 mA Logic FALSE: Transistor OFF, 0.1 mA leakage @ 50 V |
Position Output Format: BCD PLS Outputs: 3 channels, 1 setpoint pair per channel Motion Outputs: Logic TRUE: When shaft exceeds 5 RPM Output Isolation: All outputs optically isolated up to 2500 V
Upper- and Lower-Safety-Limits Output: TRUE: When press ram is positioned within the safe range (between the programmed upper- and lower-safety-limits) FALSE: When the press ram is positioned above or below the programmed upper- or lower-safety-limits
Control Inputs: Program Enable, Data Transfer, Output Enable Inputs
ELECTRICAL SPECIFICATIONS:
For units with P-Type output: TRUE: 10-28 VDC max. @ 13.5 mA max. FALSE: <2 V or open circuit
For units with N-Type output: TRUE: <2 V @ 13.5 max.; or contact closure to DC common FALSE: 10-28 VDC or open circuit
Data Transfer Input: Edge-triggered (i.e., data transfer on both rising- and falling-edges)Minimum 500 s pulse-width output updates within 5 ms of transition (<1 ms, typ.) |