c l o s e  t h i s  w i n d o w
a v g   a u t o m a t i o n - a u t o t e c h   c o n t r o l s
position / motion feedback sensing

B60 Digibrake

 S P E C I F I C A T  I O N S


Input Power:
230, 380, 460, 575 VAC 12.5%, 3-phase, 50 or 60 Hz

Operating temperature: -20 F to +122 F (-28.89 C to +50 C)

Current Setting: 20% to 100% of full scale by 2-digit thumbwheels

Accuracy: 5% of current setting

Duty Cycle: 50% up to 150 A, 10% above 150 A.

Enclosure: 12" x 10" x 6.5" (304.8 mm x 254 mm x 165.1 mm) open-frame, 12" x 10" x 7" (304.8 mm x 254 mm x 177.8 mm)


NEMA 12, for brakes up to 300 A. Consult the factory for higher ratings.

Interlock Relays: Plug-in relay, contacts rated at 120 VAC, 10 A resistive

Motion Sensor: One Form C, Plug-in relay, contacts rated at 120 VAC, 10 A resistive

E, D Options: Isolated set of contacts

R Option: Contacts rated at 120 VAC, 10 A resistive