PLC COMMUNICATION:
Through input and output registers Slots: . . . . . . . . . . . . . . . . one I/O Addresses: . . . . . 6 In/6 Out
POWER REQUIREMENTS:
Backplane: 5 VDC @ 650 mA Customer (Power Input): 24 VDC ± 15% @ 100 mA
ENVIRONMENTAL CONDITIONS:
Operating temperature: -10 to +130 °F (-23 to +55 °C) Relative humidity: 5 to 95% noncondensing
RESOLVER INTERFACE:
Position transducer: Resolver, Autotech Series RL100 or E7R Resolver cable: Overall foil shielded, twisted-pair, such as Autotech's cable: CBL-10T22-XXX, 2,500 ft. max. Cable length between resolver and module: 2,500 ft. (762 m) max. shielded
PROGRAMMING:
All features programmable from keypad, IBM-compatible PC, or through the PLC backplane. Number of PLS setups: . . . . . . eight PLS setpoints: 160 per PLS setup Scale factor: Programmable from 16 to 999 Offset: Programmable from zero to Scale Factor value Speed Compensation: Programmable for each PLS channel. Leading-Edge & Trailing Edge Speed Compensation is available Low and high motion limits: Programmable from zero to 1,999 RPM
RESPONSE TIMES:
PLS outputs: 1.6 msec (0.8 msec. version available) Tach. Update Time: 15 msec. Position, Tach., and Output Status available to backplane: Every 1.6 msec., typical (0.8-msec. version available) |
CONTROL INPUTS:
Electrical Specifications (all inputs): Optical Isolation: 2,500 Vrms Input impedance: 7,500 Logic Levels TRUE: 20 to 30 VDC; 3 mA @ 24 VDC FALSE: 0 to 2 VDC or open circuit Program Enable (PE): When TRUE, enables setpoint programming Supervisor Enable (SE): When TRUE, enables setpoint programming. Output Enable (OE): When TRUE, PLS Channel outputs enabled (Both Fault and Motion always enabled).
INPUTS:
ModZ Input (mutually exclusive with Brake Wear Monitor): ModZ inputs when TRUE enables Modification to Zero Brake Input (BI): Input BI must be TRUE when brake is applied (Clutch disengaged) Input BI must be FALSE when brake is disengaged (Clutch is applied) Brake Clear (BC): Brake Clear when TRUE clears Stopping Time and returns to Caution Condition
OUTPUTS:
Fault Output: Normally energized; deenergizes if broken resolver wire or internal fault is detected. Motion Output: Output energized whenever resolver RPM is between programmed motion limits. PLS Outputs: Number of PLS Outputs: 16
OUTPUT SPECIFICATIONS:
Customer power: 24VDC Nominal ± 15% All Outputs (16 PLS, Fault, and Motion): N-type or P-type (factory ordered) Up to 2 Amp per output; 10 Amp total per module Optical Isolation: 5,000 Vrms |